SmartView-Ethernet-Extenders-2100-SVE
Rath Janus

SmartView Ethernet Extenders 2100-SVE

Only available in
USA
COMPLIANT WITH
ASME-and-CSA-logo
ASME /CSA
IBC-and-ICC-logo
IBC/ICC
Overview
The 2100-SVE SmartView Ethernet Extenders supplies an extra 1A to the SmartView Controller. It extends over 1-pair of wiring.
Play
SmartView Two-Way Elevator Visual Communication System
2100-SVE-diagram

Dimensions: 1" H x 3.7" W x 2.75" D

Power Requirements:

  • Injector Power:56V-65W power adapter with dc jack included (120vac power cord). Requires backed up 120v source or RATH RP7700104S
  • Extender Power: Supplies 1A to the SmartView Controller

Wiring Requirements:
Extender Wiring:

  • Extends up to 1,640 feet over single pair of wiring between extenders (requires single pair, 18-24ga, shielded or unshielded)
  • CAT5E with RJ45 connectors required from network switch and the SmartView Controller to each extender
  • Main Unit (Injector) has LAN In (internet connection) and LRP Out (two wire connection)
  • Remote Unit (Extender) has LRP In (two wire connection from main unit) and PoE Out (Ethernet connection to SmartView Controller)

Additional Features:

  • Included RJ45 adapters for Interlink Cabling
  • Supplies power and communication to the SmartView Controller

Specifications:

  • Environmental: -49°F to 168°F (-45°C to 76°C)
  • Mounting: Behind the Panel

Warranty: 2 years

York Racecourse modernises its lifts for improved experience
Unitas, Stoke City Council wins with full lift safety package
Oldest Inn in Germany Installs Latest Lift Safety Technology
Digital Switch in Spain: digitalising emergency lift phones